Children’s Prosthetic Systems

By William J. Hanson, MS, Steve Mandacina, CP, FAAOP

Figure 1

Figure 1

Children's activities often place severe demands on their prosthetic systems. Children are not just small adults, yet for many years pediatric upper-limb prostheses were simply smaller, less-versatile versions of their adult counterparts. Before technology gave us the means to accommodate children's unique size, strength, and lifestyle characteristics, we regularly saw children refusing to wear their prosthetic arms, or trying to wear arms with substandard design and components. Not wanting to see their children struggling, parents sometimes were unable or unwilling to provide the necessary motivation.

Fortunately, those days are over.

Technological advances in microprocessors, batteries, and socket design have opened the door for the success of children with prosthetic arms. The newest upper-limb

prosthetic technology makes it possible to create children's prostheses that are smaller, lighter, more lifelike, more comfortable, more functional, and easier to repair than ever before [Figure 1].

Since children are still developing, their prosthetic systems must be able to grow with them, both physically and functionally. Changes in fitting protocols and components now allow these prosthetic systems to grow with the child.

Advances in Batteries, Design, Components

Children's hands create unique size and weight constraints for prosthetic components. Batteries, wrist units, and the hands themselves must be smaller and lighter than adult models. Since the battery is the heaviest component in the system after the electric hand, it is important that prosthetic controllers use energy wisely. The new classes of controller circuits have energy-saving features to conserve battery power, and they can operate with smaller, lighter Lithium-ion (Li-ion) batteries. Li-ion batteries provide up to 100 percent more battery capacity than traditional Nickel-Cadmium (NiCad) batteries, yet weigh 20 percent less.

Figure 2

Figure 2

High-capacity Li-ion batteries make it possible to operate a child's prosthesis for a full day or more. The small, built-in batteries are concealed, so the outer prosthesis is more attractive, and it is easy for children to recharge their battery by simply plugging the charger cord into a connector on the forearm [Figure 2]. With the older style batteries, when a prosthetic arm lost power--at school, for example--the child had to go through the rest of the day without use of the arm. A full recharge took more than five hours. With the new Li-ion batteries, a quick 30-minute charge will provide enough power to allow full use of the prosthesis for the remainder of the day. But with the increased capacity of these new batteries, loss of power can usually be avoided altogether.

Advancements in lightweight components, coupled with a drastic socket design change within the past five years, allow children to be fit at a much earlier age. We are now successfully fitting electric arms on infants less than one year old. New sockets allow for children to maximize function through an increased range of motion, control of the electronics, inherent suspension without the need for sleeves or straps, and all-day wearing comfort. The single most important advantage of early fitting is the immediate acceptance of the prosthetic arm by the child. No longer just a "helper-hand," the prosthesis is a normal part of their body [Figure 3 on page 38].

Rehab Roles Must Continue

Throughout the child's life, the aggressive roles of the rehabilitation team must continue. Comparison of computerized documentation of prosthetic usage and EMG signals allows the rehab team to assess proper therapy protocols and insurance justification for therapy continuance. Electronic adjustments to the prosthesis provide better function as the child develops finer control of the residual limb musculature. Adjustments of the electronics, such as gains and thresholds, must be made as muscle control and stamina increase in the growing child. The new microprocessor-based controllers allow practitioners to make instant changes to adjust the prosthesis to the precise level of optimal control.

Figure 3

Figure 3

Because of the early age of fitting, some children cannot differentiate between two muscle groups, so they are fit as a single-site control. Although a single control site can still offer proportional control of speed and grip strength, it is not as efficient as dual-site control. However, with increased time of wearing and adequate therapy, children are able to differentiate antagonistic muscle groups at approximately three years of age. Once this differentiation is developed, it is possible to switch the single-site to a dual-site control with a simple office visit adjustment. In the past, making this change required new components or even a whole new prosthesis. Dual-site control offers true EMG signal through the electrode, rather than a rub-up-against-the-electrode, threshold type of control.

Advances Increase Parental Acceptance

Since most of these advancements are relatively new to the field of prosthetics, we do not yet have long-term outcomes. However, those who have worn prosthetics as children do have one thing in common: most attribute their current success with the prosthesis to the involvement and motivation given by their parents. The advancements in electronics and socket design have been helpful in increasing parental involvement and acceptance of a child's prosthesis as well. Gone are the days of the frightening-looking hook and cumbersome harness. Today, parents see their children benefit from a comfortable prosthesis with a soft contouring socket that allows for growth and a natural-looking hand. This increase in parental acceptance is especially seen after the parents view the ease of electronic adjustments and witness their children wanting to wear the arm, rather than feeling they have to wear it because Mom told them to.

Ultimately, parental involvement, improved socket design, and computerized controllers lead to more children wearing electric arms at an earlier age and being more successful and functional than in years past. This success drives the technology forward and results in continuous improvements, providing new clinical and technological opportunities in pediatrics.

William Hanson, MS, is president of Liberating Technologies, Inc., Holliston, Massachusetts, a company which designs and

Stephen Mandacina, CP, FAAOP, is manager of the Hanger P&O Upper-Extremity Pediatrics Program and a national specialist for Hanger’s Upper-Extremity Program. He lives in Kansas City, Missouri, but travels full time fitting patients and presenting on UE pr


Related Articles

Returning Upper-Extremity Amputees to Work - August 2005
As those who work in amputee healthcare fields agree, there is much more to rehabilitation than fitting an amputee with the appropriate device. Feature

Upper-Extremity Patient Care: Personal Visions - May 2003
Exclusively Online

Future Trends in Upper Extremity Prosthetics: What Do the Experts See? - March 2003

Upper Extremity Prosthetics: Thinking Outside the Box - February 2003
Feature

Outcomes Measurements in Upper-Limb Prosthetics: Why So Elusive? - January 2003
Feature - Exclusively Online

The State of the Art in Upper-Limb Prosthetics: Reflections from Respected Voices - January 2003
We compiled a list of experienced leaders in the field of upper-limb prosthetics, drafted a list of thought-provoking questions, and collected insightful and illuminating responses in a series of separate interviews. Feature




Table Of Contents - May 2003


Physiatry: The Medical Rehabilitation Specialty
Physical medicine and rehabilitation (PM&R) "is often called the ‘quality-of-life' profession because its aim is to restore optimal patient functioning…" Feature

O&P Research: A Question of Quality—or Quantity?
Research requires three factors: expertise, time, and money.

Academy Meeting Focuses on Best, Latest in O&P
“Education is not the filling of a pail, but the lighting of a fire" Association Spotlight

Children’s Prosthetic Systems
Microprocessor Technology Opens the Door to Success

Upper-Extremity Patient Care: Personal Visions
Exclusively Online

Project to Aid Scoliosis Patients in Developing Countries
Global View

Here Comes HIPAA Security
DC Direct

Youngster Enjoys His Favorite Sports
Today's Consumer

Pedorthics Program Helps Fulfill Teen’s Wish
Stepping Out

SMART Device Provides New-Found Freedom
Innovations

Jim Russ Honored at Roast & Toast

Dale Perkins, CPO
Profiles

Neg Reg: We Have Met the Enemy, and It Is Us!
Perspective

From The Editor
Viewpoints


About The O&P EDGE
Advertisers

South West Ortho Designs
What do our customers think?

Brightree
Take control of what you can.

Becker
Security. Freedom. Convenience. Model 2009 Automatic Ring Lock Knee Joint

View All Advertisers


Print this article

Print this article

Email this article

Email this article

oandp.com  >  The O&P EDGE  >  Archives   >  February 2003

News & Articles | Classifieds | Calendar | Archives
Free Subscription | Advisory Board | Advertisers | Media Kit | Contact Us

Home | Products & Services | O & P Facilities | Resources
Amputees | Technicians | Profiles | Sports | Organizations | Networks | Publications | Education | Research | Contact Us